Type TFP

For critical air cleanliness and very critical hygiene requirements, suitable for ceiling installation

Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology

  • Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements
  • Easy, time-saving, and secure filter change
  • Diffuser face is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change without tool
  • Robust, welded construction
  • Compact construction, suitable for low ceilings
  • Various diffuser face plates to ideally meet individual requirements
  • Horizontal or vertical connection
  • Removable spigot for installation into closed ceilings in case of horizontal connection
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Meets the hygiene requirements of VDI 6022

small_tab1_Serie TFP
  • Application
  • Description

Application

  • Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry
  • Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air

Special characteristics

  • Compact construction
  • Flush ceiling installation
  • Removable spigot for installation into closed ceilings
  • Diffuser face plate can be hinged down

Nominal sizes [mm]

  • 400, 500, 600, 625

Variants

  • TC: Top entry circular spigot
  • SC: Side entry circular spigot
  • SCR: Side entry circular spigot, removable

Construction

  • Sheet steel, powder-coated RAL 9010, pure white

Attachments

  • FD: Ceiling swirl diffuser
  • TDF: Ceiling swirl diffuser

Useful additions

  • Mini Pleat filter panels (MFP)
  • Suitable filter elements to be ordered separately

Construction features

  • Welded filter casing with sealing frame for fitting filter elements, with a seal on the downstream side
  • Mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube

Materials and surfaces

  • Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white

Standards and guidelines

  • Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 1946 Part 4, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA 104-01 and SWKI 99-3, and EN 13779

Maintenance

  • Diffuser face plate can be hinged down to facilitate disassembly and cleaning
  • Particulate filter need not be removed for cleaning (seal on downstream side)
  • Easy change of filter elements due to special frame profile; no additional fluid sealing frame is necessary

Technical information

Function, Specification text, Order code, Related products

  • Function
  • Specification text
  • Order code
tfp

Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry.

Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air.

Welded filter casing with sealing frame for fixing the Mini Pleat filter panels, with a fluid seal on the downstream side.

With top entry or side entry spigot; removable spigot as an option.

The Mini Pleat filter panels are pressed into place using a tensioning frame with knurled screws.

Casing with mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube.

Diffuser face plate made of sheet steel, powder-coated (RAL 9010), types FD and TDF; can be hinged down to facilitate disassembly and cleaning.

Leakage test for each casing.

Special characteristics

  • Compact construction
  • Flush ceiling installation
  • Removable spigot for installation into closed ceilings
  • Diffuser face plate can be hinged down

Materials and surfaces

  • Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white

Construction

  • Sheet steel, powder-coated RAL 9010, pure white

tfp

Variants, Dimensions and weight, Product details

  • Variants
  • Dimensions and weight

TFP-TC

  • Gehäuse mit rundem Anschlussstutzen
  • Anschlussstutzen oben angeordnet

TFP-SC

  • Gehäuse mit rundem Anschlussstutzen
  • Anschlussstutzen seitlich angeordnet

TFP-SCR

  • Gehäuse mit rundem Anschlussstutzen
  • Anschlussstutzen seitlich angeordnet
  • Anschlussstutzen demontierbar

Alle Gewichtsangaben sind netto, ohne Verpackung

Filtergröße
B × H × T K M J L kg

400

295 × 295 × 85

158

250

365

371

398

340

10

500

395 × 395 × 85

198

250

465

471

498

440

15

600

495 × 495 × 85

198

250

565

571

598

540

21

625

520 × 520 × 85

198

250

590

596

623

565

23

③ Außenmaß Luftdurchlass ④ Außenmaß Gehäuse ⑤ Außenmaß Gehäuseflansch ⑥ Lochabstand Aufhängung oben ⑦ Gewicht (ca.)


Filtergröße
B × H × T K M J L G kg

400

295 × 295 × 85

158

350

365

371

398

340

265

11

500

395 × 395 × 85

198

350

465

471

498

440

245

16

600

495 × 495 × 85

198

350

565

571

598

540

245

22

625

520 × 520 × 85

198

350

590

596

623

565

245

24

③ Außenmaß Luftdurchlass ④ Außenmaß Gehäuse ⑤ Außenmaß Gehäuseflansch ⑥ Lochabstand Aufhängung oben ⑦ Anschlussmaß bis Stutzenmitte ⑧ Gewicht (ca.)


Filtergröße
B × H × T K M J L G kg

400

295 × 295 × 85

158

350

365

371

398

340

255

11

500

395 × 395 × 85

198

350

465

471

498

440

235

16

600

495 × 495 × 85

198

350

565

571

598

540

235

22

625

520 × 520 × 85

198

350

590

596

623

565

235

24

③ Außenmaß Luftdurchlass ④ Außenmaß Gehäuse ⑤ Außenmaß Gehäuseflansch ⑥ Lochabstand Aufhängung oben ⑦ Anschlussmaß bis Stutzenmitte ⑧ Gewicht (ca.)


Installation details, Basic information and nomenclature

  • Installation details

Installation and commissioning

  • Fitting of filter elements with a fluid seal on the downstream side
  • The filter element is pressed into place using a tensioning frame with knurled screws
  • Diffuser face plate is hinged and held in place by magnets; no additional tools required

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.


Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request.
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request.
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +971 4 3417448 | Fax: +971 4 3417449