00136706_0
DID-E


00132715_0
Tested to VDI 6022


00137207_0
Eurovent certification


00134036_0
Water connections


00131442_0
Induced air and supply air grilles from our portfolio


00136706_0
00132715_0
00137207_0
00134036_0
00131442_0

DID-E

Active chilled beam with one-way air discharge and horizontal heat exchanger, in nominal lengths of 900, 1200 and 1500 mm

Active chilled beam for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for installation into bulkheads, e.g. in hotel rooms

  • Preferably for room heights up to 4.00 m
  • High heating and cooling capacity with a low conditioned primary air volume flow rate and low sound power level
  • High comfort levels due to low airflow velocity in the occupied zone
  • Three nozzle variants to optimise induction based on demand
  • Fixing points for various types of suspension


Optional equipment and accessories

  • Control system
  • Induced air spigot and supply air spigot (to facilitate attaching the grilles)
  • Heat exchanger powder-coated black
  • Powder coating in many different colours, e.g. RAL CLASSIC

Application

Application

  • Active chilled beams of Type DID-E for installation into ceiling bulkheads, preferably for room heights up to 4.00 m
  • Particularly suitable for hotel bedrooms and rooms on hospital wards
  • 2-pipe or 4-pipe heat exchangers enable good comfort levels with a low conditioned primary air volume flow rate
  • Energy-efficient solution since water is used for heating and cooling

Special characteristics

  • Choice of any induced air grille and supply air grille from our portfolio
  • One-way air discharge
  • Horizontal heat exchanger as 2-pipe or 4-pipe system
  • Internal nozzle plate with punched nozzles (non-combustible)
  • Water connections at the narrow side, Ø12 mm Cu pipe, with plain tails or with G½" external thread, or with a G½" union nut; with flat seal

Nominal sizes

  • 900, 1200, 1500 mm

Description

Variants

  • Heat exchanger width is 256 or 320 mm


Heat exchanger

  • 2: 2-pipe systems
  • 4: 4-pipe systems


Nozzle variants

  • G: Large
  • U: Extra large
  • 2U: Two nozzle rows, extra large nozzles

Attachments

  • Water connection A1: G½" external thread and flat seal
  • Water connection A2: G½" union nut and flat seal

Accessories

  • IS: Induced air spigot
  • AS: Supply air spigot
  • IA: Induced and supply air spigots

Useful additions

  • Connecting hoses
  • Control equipment consisting of a control panel including a controller with integral room temperature sensor; valves and valve actuators; and lockshields
  • Ventilation grille
  • X-AIRCONTROL control system

Construction features

  • Spigot is suitable for circular ducts to EN 1506 or EN 13180
  • Three nozzle variants to optimise induction based on demand
  • Four suspension points for on-site installation (by others)

Materials and surfaces

  • Casing and nozzle plate made of galvanised sheet steel
  • Heat exchanger with copper tubes and aluminium fins
  • Casing, primary air spigot, etc., either galvanised or in black (RAL 9005)
  • Heat exchanger also in black (RAL 9005)
  • Optional induced air spigot (IS) and supply air spigot (AS) made of galvanised sheet steel; black (RAL 9005) as an option

Standards and guidelines

  • Products are certified by Eurovent (no. 09.12.432) and listed on the Eurovent website
  • Declaration of hygiene conformity to VDI 6022

Maintenance

  • No moving parts, hence low maintenance
  • The heat exchanger can be vacuumed with an industrial vacuum cleaner if necessary
  • VDI 6022, Part 1, applies (Hygiene requirements for ventilation and air-conditioning systems and units)

Technical information

Function, Technical data, Quick sizing, Specification text, Order code, Related products

  • FUNCTION
  • TECHNICAL DATA
  • QUICK SIZING
  • Specification text
  • ORDER CODE

Functional description

Active chilled beams provide centrally conditioned primary air (fresh air) to the room and use heat exchangers for additional cooling and/or heating.

The primary air is discharged through nozzles into the mixing chamber; as a result of this, secondary air (room air) is induced via the induced air grille and passes through the horizontal heat exchanger.

Primary and secondary air mix and are then supplied to the room horizontally through the supply air grille.

Nominal length

900, 1200, 1500 mm

Length

948, 1248, 1548 mm

Width

550, 614 mm

Height

200 mm (plus induced air grille)

Primary air spigot, diameter

158 mm

Primary air volume flow rate

10 – 78 l/s or 36 – 281 m³/h

Cooling capacity

Up to 1730 W

Heating capacity

Up to 1480 W

Max. operating pressure, water side

6 bar

Max. operating temperature

75 °C


The quick sizing table contains operating points for defined reference units. For other operating points you may use the Easy Product Finder design software.

Quick sizing – heat exchanger width 256 mm

LN Primary air Cooling Heating
LN VPr Δpt LWA 2-pipe and 4-pipe systems 4-pipe system
LN VPr Δpt LWA Qtot QWK ΔtW Δpw QWH = Qtot ΔtW Δpw
LN l/s m³/h Pa dB(A) W K kPa W kPa

900

G

7

25

38

<20

262

178

1.4

1.4

313

2.4

0.5

900

G

12

43

111

<20

507

363

2.8

1.4

658

5.1

0.5

900

G

17

61

224

29

673

468

3.7

1.4

863

6.7

0.5

900

U

13

47

40

<20

470

314

2.5

1.4

565

4.4

0.5

900

U

21

76

105

20

692

439

3.4

1.4

805

6.3

0.5

900

U

29

104

200

30

865

515

4.0

1.4

958

7.5

0.5

900

2U

25

90

38

<20

622

320

2.5

1.4

577

4.5

0.5

900

2U

41

148

103

26

957

457

3.6

1.4

842

6.6

0.5

900

2U

57

205

200

36

1227

540

4.2

1.4

1007

7.9

0.5

1200

G

9

32

35

<20

323

214

1.7

1.7

380

3.0

0.6

1200

G

15

54

98

<20

617

437

3.4

1.7

801

6.3

0.6

1200

G

21

76

192

28

815

561

4.4

1.7

1052

8.7

0.6

1200

U

17

61

39

<20

600

395

3.1

1.7

721

5.6

0.6

1200

U

28

101

106

22

891

553

4.3

1.7

1035

8.1

0.6

1200

U

39

140

206

32

1116

646

5.1

1.7

1227

9.6

0.6

1200

2U

33

119

39

<20

804

406

3.7

1.7

742

5.8

0.6

1200

2U

54

194

104

30

1273

572

4.5

1.7

1073

8.4

0.6

1200

2U

75

270

200

40

1573

668

5.2

1.7

1275

10.0

0.6

1500

G

12

43

40

<20

444

299

2.3

2.1

537

4.2

0.7

1500

G

20

72

117

21

793

552

4.3

2.1

1033

8.1

0.7

1500

G

28

101

220

31

1028

690

5.4

2.1

1321

10.3

0.7

1500

U

21

76

38

<20

724

471

3.7

2.1

869

6.8

0.7

1500

U

35

126

107

24

1078

656

5.1

2.1

1249

9.8

0.7

1500

U

49

176

210

34

1352

761

5.9

2.1

1474

11.5

0.7

1500

2U

41

144

40

21

981

486

3.8

2.1

900

7.0

0.7

1500

2U

60

216

85

32

1358

635

5.0

2.1

1204

9.4

0.7

1500

2U

80

288

152

41

1699

734

5.7

2.1

1416

11.1

0.7

① Nozzle variant ② Air-regenerated noise


Quick sizing – heat exchanger width 320 mm

LN Primary air Cooling Heating
LN VPr Δpt LWA 2-pipe and 4-pipe systems 4-pipe system
LN VPr Δpt LWA Qtot QWK ΔtW Δpw QWH = Qtot ΔtW Δpw
LN l/s m³/h Pa dB(A) W K kPa W kPa

900

G

7

25

38

<20

284

199

1.6

1.6

337

2.6

0.5

900

G

12

43

111

<20

548

403

3.2

1.6

705

5.5

0.5

900

G

17

61

224

29

722

517

4.0

1.6

923

7.2

0.5

900

U

13

47

40

<20

506

349

2.7

1.6

606

4.7

0.5

900

U

21

76

105

20

739

485

3.8

1.6

862

6.7

0.5

900

U

29

104

200

30

918

568

4.4

1.6

1073

8.0

0.5

900

2U

25

90

38

<20

658

357

2.8

1.6

619

4.8

0.5

900

2U

41

148

103

26

1000

506

4.0

1.6

901

7.0

0.5

900

2U

57

205

200

36

1281

594

4.6

1.6

1076

8.4

0.5

1200

G

9

32

35

<20

349

240

1.9

2.2

409

3.2

0.6

1200

G

15

54

98

<20

664

483

3.8

2.2

858

6.7

0.6

1200

G

21

76

192

28

871

617

4.8

2.2

1123

8.8

0.6

1200

U

17

61

39

<20

643

438

3.4

2.2

772

6.0

0.6

1200

U

28

101

106

22

946

609

4.8

2.2

1105

8.6

0.6

1200

U

39

140

206

32

1178

707

5.5

2.2

1308

10.2

0.6

1200

2U

33

119

39

<20

849

451

3.5

2.2

795

6.2

0.6

1200

2U

54

194

104

30

1780

628

4.9

2.2

1145

9.0

0.6

1200

2U

75

270

200

40

1636

731

5.7

2.2

1358

10.6

0.6

1500

G

12

43

40

<20

478

333

2.6

2.7

577

4.5

0.7

1500

G

20

72

117

21

849

608

4.8

2.7

1103

8.6

0.7

1500

G

28

101

220

31

1092

754

5.9

2.7

1406

11.0

0.7

1500

U

21

76

38

<20

774

520

4.1

2.7

930

7.3

0.7

1500

U

35

126

107

24

1140

718

5.6

2.7

1330

10.4

0.7

1500

U

49

176

210

34

1420

829

6.5

2.7

1567

12.2

0.7

1500

2U

41

144

40

21

1031

537

4.2

2.7

962

7.5

0.7

1500

2U

60

216

85

32

1419

696

5.4

2.7

1283

10.0

0.7

1500

2U

80

288

152

41

1765

800

6.3

2.7

1505

11.8

0.7

① Nozzle variant ② Air-regenerated noise


Reference values

Parameter Cooling Heating

tR

26 °C

22 °C

tPr

16 °C

22 °C

tWV

16 °C

50 °C

VW

110 l/h

110 l/h


Active chilled beams of Type DID-E, with one-way air discharge and high thermal output, providing high thermal comfort levels.

For installation into ceiling bulkheads, preferably in rooms with a height up to 4.00 m.

The units consist of a casing with suspension points, a spigot, non-combustible nozzles, and a horizontal heat exchanger.

Three nozzle variants to optimise induction based on demand.

Special characteristics

  • Choice of any induced air grille and supply air grille from our portfolio
  • One-way air discharge
  • Horizontal heat exchanger as 2-pipe or 4-pipe system
  • Internal nozzle plate with punched nozzles (non-combustible)
  • Water connections at the narrow side, Ø12 mm Cu pipe, with plain tails or with G½" external thread, or with a G½" union nut; with flat seal

Materials and surfaces

  • Casing and nozzle plate made of galvanised sheet steel
  • Heat exchanger with copper tubes and aluminium fins
  • Casing, primary air spigot, etc., either galvanised or in black (RAL 9005)
  • Heat exchanger also in black (RAL 9005)
  • Optional induced air spigot (IS) and supply air spigot (AS) made of galvanised sheet steel; black (RAL 9005) as an option

Technical data

  • Nominal length: 900, 1200, 1500 mm
  • Length: 948, 1248, 1548 mm
  • Height: 200 mm (plus induced air grille)
  • Width: 550, 614 mm
  • Primary air spigot, diameter: 158 mm
  • Primary air volume flow rate: 10 – 78 l/s or 36 – 281 m³/h
  • Cooling capacity: up to 1730 W
  • Heating capacity: up to 1480 W
  • Max. operating pressure: 6 bar
  • Max. operating temperature: 75 °C

Sizing data

Primary air

  • V _______________________ [m³/h]
  • Δpt _______________________ [Pa]

Air-regenerated noise

  • LWA _______________________ [dB(A)]

Cooling

  • Qges _______________________ [W]

Heating

  • Qges _______________________ [W]

This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme.

00132991_0

 Type
DID-E       Active chilled beam

 Heat exchanger
2       2-pipe
4       4-pipe

 Nozzle variant
G       Large
U       Extra large
2U       Two rows, extra large

 Arrangement of water connections
RE       Right side
LI       Left side

 

 Water connections
       No entry: Ø12 mm pipe with plain tails
A1       With G½" external thread and flat seal
A2       With G½" union nut and flat seal

 Vent
       No entry: none
E       With

 Nominal length × width of heat exchanger [mm]
       LN × BWT
900 × 256
900 × 320
1200 × 256
1200 × 320
1500 × 256
1500 × 320

 Surface of casing and heat exchanger
       No entry: untreated
G1       RAL 9005, black

 Valves and actuators
       No entry: none
VS       With valves and actuators

DID-E-2-G-RE/900×256

Heat exchanger

2-pipe

Nozzle variant

Large

Arrangement of water connections

Right side

Nominal length × width of heat exchanger

900 × 256 mm


DID-E-4-2U-RE-A1-E/1200×320/G1/VS

Heat exchanger

4-pipe

Nozzle variant

2 rows, extra large

Arrangement of water connections

Right side

Water connections

G½" external thread and flat seal

Extract ventilation

With

Nominal length × width of heat exchanger

1200 × 320 mm

Surface of casing and heat exchanger

RAL 9005, black

Valves and actuators

With


 

Variants, Dimensions and weight

  • Variants
  • Dimensions and weight
DID-E 00100488_0......
① Water connections on the left (LI)
② Water connections on the right (RE)

¹min.
²max.


Dimensions [mm]

LN BWT L BX BY E X Y

900

256

948

550

576

160

221

225

900

320

948

614

640

224

318

257

1200

256

1248

550

576

160

221

225

1200

320

1248

614

640

224

318

257

1500

256

1548

550

576

160

221

225

1500

320

1548

614

640

224

318

257


Weight [kg]

Nominal length (LN) 900 × 256 900 × 320 1200 × 256 1200 × 320 1500 × 256 1500 × 320

DID-E

18

22

21

26

25

31

Contained water (max.)

1.8

2.3

2.4

3.0

3.0

3.8

Induced air spigot

1.8

2.0

2.3

2.5

2.8

3.0

Supply air spigot

1.7

1.7

2.2

2.2

2.7

2.7


Installation details, Basic information and nomenclature

  • Installation details
  • BASIC INFORMATION AND NOMENCLATURE

Installation and commissioning

  • Preferably for rooms with a clear height up to 4.00 m
  • Installation into ceiling bulkheads
  • Side entry primary air spigot
  • Lengths of 948, 1248, and 1548 mm, and width of 576 mm (heat exchanger 256 mm) or 640 mm (heat exchanger 320 mm)
  • Installation and connections to be performed by others; fixing, connection and sealing material to be provided by others
  • Active chilled beam has 4 suspension points (Ø6.4 mm) for on-site installation (by others)
  • Heat exchangers are fitted with water flow and water return connections at the narrow side
  • Induced and supply air spigots (accessories) facilitate mounting the grilles (an installation subframe for the concealed screw fixing is not required)
  • If the cover for the induced air opening is provided by others, e.g. with a perforated plate, that plate must have a free area of at least 65 %.

LN [mm]

Nominal length

LWA [dB(A)]

Sound power level

tPr [°C]

Primary air temperature

tWV [C°]

Water flow temperature – cooling/heating

tR [C°]

Room temperature

tR [C°]

Room temperature

tAN [C°]

Secondary air intake temperature

QPr [W]

Thermal output – primary air

Qtot [W]

Thermal output – total

QW [W]

Thermal output – water side, cooling/heating

VPr [l/s]

Primary air volume flow rate

VPr [m³/h]

Primary air volume flow rate

VW [l/h]

Water flow rate – cooling/heating

V [l/h]

Volume flow rate

∆tW [K]

Temperature difference – water

∆pW [kPa]

Pressure drop, water side

∆pt [Pa]

Total pressure drop, air side

∆tPr = tPr - tR [K]

Difference between primary air temperature and room temperature

∆tRWV = tWV - tR [K]

Difference between water flow temperature and room temperature

∆tWm-Ref [K]

Difference between mean water temperature and reference temperature

LN [mm]

Nominal length

Mixed flow

The supply air is discharged from the diffuser into the space with a velocity between 2 and 5 m/s. The resulting air jet mixes with the room air, ventilating the entire space. Mixed flow systems typically provide a uniform temperature distribution and air quality within the space. The originally high velocity of the turbulent air jet decreases rapidly due to the high induction levels of mixed flow systems.

Heat exchanger

The maximum water-side operating pressure for all heat exchangers is 6 bar.

The maximum water flow temperature (heating circuit) for all heat exchangers is 75 °C; if flexible hoses are used, the water flow temperature should not exceed 55 °C. Units for other pressures and temperatures are available on request.

The water flow temperature (cooling circuit) should be at least 16 °C such that it does not permanently fall below the dew point. For units with a condensate drip tray the water flow temperature may be reduced to 15 °C.

Heat exchanger as 2-pipe system

Air-water systems with a 2-pipe heat exchanger may be used for either heating or cooling. In changeover mode it is possible to use all units within a water circuit exclusively for cooling in summer and exclusively for heating in winter.

Heat exchanger as 4-pipe system

Air-water systems with a 4-pipe heat exchanger may be used for both heating and cooling. Depending on the season, i.e. especially in spring and autumn, it may be possible that an office has to be heated in the morning and cooled in the afternoon.

Downloads

product information

certificates

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Contact

We are here for you

Please specify your message and type of request.
Tel.: +971 4 3417448 | Fax: +971 4 3417449

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +971 4 3417448 | Fax: +971 4 3417449